Roche Integra 400 PlusThe pressure for laboratories to work more efficiently has never been higher, increasing the need for innovative solutions. With the COBAS INTEGRA 400 plus, innovation means 4 on-board measurement technologies, robotic handling of reaction cuvettes and improved operator ergonomics. This supports the very broad menu and ease-of-use required for true workload consolidation, leading to efficiency gains only possible with only one analytical platform, one user interface & one reagent system. Sample selective bench top analyser for small to mid-size laboratories. Flexible system for consolidating routine workload with a capacity of 36 tests (including 4 ISE: Na+, K+, Li+, Cl-) on board and a throughput up to 400 test per hour.
- Electrical Requirements - 100-125 / 200-240 Volts AC, 50 or 60Hz, Consumption 1200VA
- Physical Dimensions - Width: 135cm (53.1in); Depth:66cm (25.9in); Height: 75cm (28.5in)
- Weight - 230kgs (506lbs)
- Water Requirements - Up to 2 liters per hour in operating mode, Type 1 NCCLS
- Certification - CE, UL, C-UL
Specifications Sample materials - Biological fluids including whole blood* (*with decreased immersion depth) Technologies - Photometry, Turbidimetry, Fluorescence Polarisation Cycle time - 10.6sec (COBAS INTEGRA 800 6sec) Absorbance wavelengths (nm) (primary and secondary) - 340, 378, 409, 480, 512, 552, 583, 629, 652, 659, 800 Fluorescence wavelengths (nm) - 485 (excitation) 515 (transmission) Reaction modes - R1-S, R1-S-SR, R1/R2-S, R1/R2-S-SR Reaction volumes (μl) - 120-245 Sample volumes (μl) - 2-50 Measurement range (abs) - 0–2A (5mm path length) Measurement range (FP) - 0–500mP Calculation models - Linear regression, Linear interpolation, Logit / Log 4, Logit / Log 5 On board stability - User defined within cobas c pack carriers Calibration modes - User defined – each lot, each pack, or each interval
System System - Random and continuous access, sample selective analyser Integration of 4 measuring principles 36 tests on-board Absorbance Photometry: Enzymes and Substrates Turbidimetry: Specific Proteins, Drugs of Abuse Fluorescence Polarimetry: Therapeutic Drugs, Thyroid Tests Ion-Selective Electrode Potentiometry: Na+, K+, Cl– and Li+
Test Throughput - Up to 400 tests/hr (including ISE)
Sample Sample Types - Serum, Plasma, Urine, CSF, Hemolysate and Whole Blood (HbA1c)
Sample Handling - 90 primary or secondary tubes on-board Up to 6 x RD15 racks on-board Cooled rack position for controls and calibrators Automatic sample dilution and concentration Barcode reading via laser scanner, with immediate STAT recognition
Sample Container Types - Primary tubes: 5 to 10ml; 16x100, 16x75, 13x100, 13x75mm Hitachi microcup, 500µl; Hitachi standard cup, 1.5ml; COBAS cup, 650µl; Eppendorf cup, 1.5ml; Cup on tube definable
Sample Volume - Typically 2 to 10µl per test, ISE indirect 20µl, ISE direct 97µl
Sample Barcode Types - Code 128, Codabar, Code 2 of 5 interleaved, Code 39
Reagents On-board reagent capacity - 32 cassettes, 50-800 tests per cassette Up to 8 racks of 4 cassettes on-board Automatic cassette reconstitution when required Reagent compartment cooled to 10-15°C On-board stability up to 3 months, calibration typically each lot
Reaction Cells - Holds 1000 disposable cuvettes with 5mm path length and 120-240µl reaction volume
Control unit Control Unit - HP workstation running Windows XP Intel Pentium IV with 512 MB RAM Dual 40 GB hard drives, CD ROM, floppy drive and inbuilt modem
System Interfaces - RS 232 serial interface, bi-directional, modem for Remote Diagnostics access
Technical Specs Electrical Requirements - 100-125 / 200-240 Volts AC, 50 or 60Hz, Consumption 1200VA
Physical Dimensions - Width: 135cm (53.1in); Depth:66cm (25.9in); Height: 75cm (28.5in)
Weight - 230kgs (506lbs)
Water Requirements - Up to 2 liters per hour in operating mode, Type 1 NCCLS
Certification - CE, UL, C-UL
|